Reserve Power (VRLA - AGM & GEL, Pure Lead, and Flooded Tubular)

Critical Standby battery back-up applications where the energy is stored in reserve in batteries and ready for use whenever needed. Typical critical battery back-up applications are UPS (High rate applications), Telecom (long duration float application), Utility Switchgear (step loads, peak power shaving, frequency regulation, and distributed energy applications), Renewable Energy (cyclic solar/wind energy storage), Emergency Lighting (float applications), Industrial Controlled Power, Railway & Aircraft signal back-up support.

Leoch Battery Manufacturing has the most advanced manufacturing equipment and technology available today, with gravity cast grids, continuous punched grids, expanded metal grids, tubular grids, and the Premium Pure Lead punched grids for exceptional life and performance.

LRC Series

Advanced Carbon Deep Cycle AGM

The LRC Series utilizes Advanced Carbon technology for superior performance in partial-state-of-charge (PSOC) applications and a long deep cycle life of 4400 cycles @ 50% DoD. These robust, high capacity, VRLA AGM batteries are ideal for use in applications where the batteries are cycled regularly, such as: Peak load shifting energy storage systems, Load tracking energy storage systems, Grid frequency adjustment energy storage systems, mobile container storage systems and a variety of other applications.

 

LEOCH ENERGY STORAGE CATALOG

 

 

 

Additional Info

  • General Features:

    Capacity 140 to 1000AH 2V Top Terminal and 12V Front Terminal Models

    1. 15-Year Design Life
    2. Long Deep Cycle Life 4400 cycles @ 50% DOD
    3. Outstanding partial state of charge (PSOC) performance
    4. Super-Fast Charging: From 0% to 90% SoC level in less than 1.5 hours
    5. Wide Operating Temperature Range -4°F to 131°F (-20℃ to 55℃ )
    6. Doubled Shelf Life (2 years) with Low Self-discharging Rate
    7. Modular design for easy installation and maintenance
  • Typical Applications:
    1. Renewable energy power (solar, wind, PV/wind hybrid) access to energy storage systems
    2. Peak load shifting energy storage systems
    3. Load tracking energy storage systems
    4. Grid frequency adjustment energy storage systems
    5. Smart grid, micro-grid systems, mobile container storage systems
    6. Oil and electricity hybrid energy storage systems in the area without municipal electricty or with poor grid
    7. Renewable energy communication base stations, core computer rooms, IDC that with peak load shifting functions.
  • Specifications (Click on the link to see PDF):
    Model Number Nominal
    Voltage
    (V)
    Rated
    Capacity
    C10 (Ah)
    Dimensions   Weight    Terminal Type
    Length Width Height Total Height
    mm   in mm in mm in mm in Kg lbs T6-A
    LRCF12-140 12 140 550 21.7 125  4.9 315 12.4  315 12.4 55.0  121.3 T6-A
    LRCF12-170 12 170 560  22.0 126  5.0 320 12.6 320 12.6 62.0  136.7 T11
    LRC2-300 2 300 158  6.2 181 7.1  350 13.8 365 14.4 24.5 54.01  T11
    LRC2-400 2 400 191 7.5  181 7.1  350 13.8  365 14.4 31.0 68.3  T11
    LRC2-500 2 500 225  8.9 181  7.1 350 13.8  365 14.4  37.5 82.7 T11
    LRC2-600 2 600 303  11.9 181 7.1  350 13.8  365  14.4 47.5 104.7  T11
    LRC2-800 2 800 370 14.6 181  7.1 350  13.8 365  14.4 60.5 133.4 T11
    LRC2-1000 2 1000 466  18.3 181  7.1 363  14.3 378 14.9  76.0  167.6 T11

     

     

     

     

     

     

    Copyright © 1999-2015 Leoch Battery Inc All Rights Reserved 

    Service line : +86-755-8603-6060  E-mail : This email address is being protected from spambots. You need JavaScript enabled to view it.   粤 ICP 备 06076234 号